Collection Instructions: If the light blue top tube is the only tube to be drawn and will be collected using a butterfly set, a “discard” tube (either a plain[non-additive] or light blue) must be partially drawn just to completely fill the collection tubing with blood before collecting the light blue top for testing. Failure to perform this step will result in an under-filled tube that the laboratory will reject. Allow blood to fill the tube completely to the line on the tube. The ratio of blood to anticoagulant is critical in coagulation testing and at least a 90% fill is required. Immediately mix the specimen by gently inverting the tube 4-6 times to completely mix with the anticoagulant. Failure to perform this can result in a clotted sample, which is unacceptable for testing. If centrifugation of the specimen cannot be performed immediately after collection call the Laboratory for a STAT pick- up For additional coagulation assays, whole blood cannot be refrigerated or frozen.
If centrifugation is possible, and transport to the lab will not occur within 1 hour, spin down, remove the plasma to a clean plastic transport tube using a plastic transfer pipette, and spin the plasma again. Remove the plasma with a clean plastic transfer pipette to a fresh transport container and refrigerate up to 3 days this citrated platelet-poor plasma. A double centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results. Each coagulation assay requested should have its own vial of citrated plasma, 1.0 mL each.
Transport Instructions
Specimen Stability
24 Hours RT 72 Hours Refrigerated 3 Months Frozen at - 20 C