Epic Build / Desired Build Test Compendium
Welcome to the new Northwell Health Labs Epic Build / Desired Build Test Directory! Please email ClinicalLabInformatics@northwell.edu with any typos, corrections or issues.

B-Type Natriuretic Peptide(BNP)ab

Desired Epic Build * = editable field  

Cerner Primary Mnemonic: B-Type Natriuretic Peptide(BNP)ab
PDM 235312
Informatics - WorkgroupChemistry
Synonyms *B-Type Natriuretic Peptide(BNP)ab
BNP
Display Name *B-Type Natriuretic Peptide(BNP)ab
Specimen Sources (combined Order Entry and Specimen Navigator) *
Specimen Types (combined Order Entry and Specimen Navigator) *
Body Fluids (types sent through AOEs)
Specimen Navigator Specimen Types
Specimen Navigator Specimen Sources
Specimen Navigator Short Name
Ordering info (EPIC SmartText)Support a diagnosis of congestive heart failure (CHF) B-type natriuretic peptide (BNP), also referred to as brain natriuretic peptide, is a member of a family of structurally similar peptide hormones that  includes atrial natriuretic peptide.1 BNP is a 32-amino-acid peptide that contains a 17-amino-acid ring structure that is formed as the result of an  internal disulfide bond. BNP is predominantly secreted by the ventricles of the heart in response to increased pressure. BNP acts as a vasodilator  and has diuretic and natriuretic properties. BNP suppresses both sympathetic tone and the renin-angiotensin system. These physiologic effects  serve to reduce intraventricular pressure and improve the symptoms of congestive heart failure (CHF). BNP levels increase with age and can be transiently increased by vigorous exercise.1,2 BNP levels correlate with end-diastolic pressure and tend  to be increased in patients with diminished left ventricular ejection fraction.1,3 BNP levels have been shown to be useful in the diagnosis of patients  with symptoms that are consistent with CHF. Maisel and coworkers4 found that a BNP cutoff of 75 pg/mL could be used to predict systolic and/or  diastolic abnormalities accurately in symptomatic patients referred to echocardiology for left ventricular function studies. They found that this cutoff  identified patients with abnormal function from a population of 200 patients with a sensitivity of 95.9%, specificity of 86%, positive predictive value of  98%, and a negative predictive value of 89%. The overall accuracy of the diagnosis with a cutoff of 75 pg/mL was 93%. These results were similar to  those found by Dao and coworkers.5 They found that BNP levels could be used to accurately identify patients with CHF from a population of patients  presenting at the emergency room with shortness of breath (dyspnea). They found that a BNP value >80 pg/mL could be used to identify patients with  CHF from this population with a sensitivity of 97%, specificity of 98%, positive predictive value of 92%, and a negative predictive value of 98%.6 Footnotes 1. Maisel A. B-type natriuretic peptide levels: A potential novel “white count” for congestive heart failure. J Card Fail. 2001; 7(2):183-193. PubMed 11420771 2. McNairy M, Gardetto N, Clopton P, et al. Stability of B-type natriuretic peptide levels during exercise in patients with congestive heart failure: Implications  for outpatient monitoring with B-type natriuretic peptide. Am Heart J. 2002; 143(3):406-411. PubMed 11868044 3. Valli N, Georges A, Corcuff JB, et al. Assessment of brain natriuretic peptide in patients with suspected heart failure: Comparison with radionuclide  ventriculography data. Clin Chim Acta. 2001; 306(1-2):19-26. PubMed 11282090 4. Maisel AS, Koon J, Krishnaswamy P, et al. Utility of B-natriuretic peptide as a rapid, point-of-care test for screening patients undergoing echocardiography  to determine left ventricular dysfunction. Am Heart J. 2001; 141(3):367-374. PubMed 11231433 5. Dao Q, Krishnaswamy P, Kazanegra R, et al. Utility of B-type natriuretic peptide in the diagnosis of congestive heart failure in an urgent-care setting.  J Am Coll Cardiol. 2001; 37(2):379-385. PubMed 11216950 6. Wu AH, Packer M, Smith A et al. Analytical and clinical evaluation of the Bayer ADVIA Centaur Automated B-type natriuretic peptide assay in patients  with heart failure: A multisite study. Clin Chem. 2004 May; 50(5):867-873.
IP Orderable (inpatient) No
OP Orderable (outpatient) No
AOEs *

AP AOEs
Special History No
Build Comments
Filter *
Cerner Site RestrictForest Hills Hospital Laboratory
Huntington Hospital Laboratory
LabCorp
Northwell Health Laboratories
Plainview Hospital Laboratory
SIUH North Laboratory
SIUH Pouch Terminal Laboratory
Cerner Results

Result Desc Result display Result PDM
BNP BNP 5901640

Actual Epic Build 3/11/2025

PROCEDURE ID 183364
PDM 235312
ORDER DISPLAY NAME B-Type Natriuretic Peptide(BNP) ab
PROCEDURE NAME B-TYPE NATRIURETIC PEPTIDE(BNP) AB
PROCEDURE MASTER NUMBER LAB14064
SHORT PROCEDURE NAME B-TYPE NATRIURETIC PEPTIDE(BNP) AB
CATEGORY CODE 1.0
CATEGORY CODE RECORD NAME LAB BLOOD ORDERABLES
SYNONYMS B-Type Natriuretic Peptide(BNP)ab
BNP
CLINICALLY ACTIVE No
ORDERABLE No
PERFORMABLE Yes
FILTER GENOMICS
REFERENCE LINK URL
ORDERING INSTRUCTIONS
DEFAULT SPECIMEN TYPE
SPECIMEN TYPE PICK LIST
SPECIMEN TYPE LIST
OP SPECIMEN TYPE LIST
SPECIMEN SOURCE PICK LIST
SPECIMEN SOURCE DEFAULT - MALE
SPECIMEN SOURCE DEFAULT - FEMALE
SPECIMEN SOURCE LIST
OP SPECIMEN SOURCE LIST
IP LAB TEST COMPONENTS FOR REPORT BNP
OP LAB TEST COMPONENTS FOR REPORT BNP
ORDER QUESTIONS []
ORDER QUESTIONS RECORD NAME
INPATIENT ORDER QUESTIONS []
INPATIENT ORDER QUESTIONS RECORD NAME
ORDER SPECIFIC QUESTION OVERRIDE
INPATIENT QUESTION OVERRIDE
LOCATION RESTRICT LIST IP
LOCATION RESTRICT LIST IP RECORD NAME
LOCATION RESTRICT LIST INCLUDE IP
LOCATION RESTRICT LIST OP
LOCATION RESTRICT LIST OP RECORD NAME
LOCATION RESTRICT LIST INCLUDES OP
EDP AMB ORDER SPECIFIC QUESTIONS RECORD NAME
EDP IP ORDER SPECIFIC QUESTIONS RECORD NAME
EDP IP SPECIMEN SOURCE Blood, Venous
Blood, Central Line
Blood, Arterial
Blood, Capillary
EDP OP SPECIMEN SOURCE
EDP IP SPECIMEN TYPE Blood
EDP OP SPECIMEN TYPE
DERIVED EDP IP BUTTONS S
DERIVED EDP IP BUTTONS T
DERIVED EDP OP BUTTONS S
DERIVED EDP OP BUTTONS T
IP ORDERABLE
OP ORDERABLE
STANDARD LAB COMPONENTS
STANDARD LAB COMPONENTS RECORD NAME
COMPONENT DATA REQUIREMENT
EPIC OP AOEs

EPIC IP AOEs

EPIC Components (results - crosswalked through Cerner)

Component IDComponent NameBase NameCommon NameExternal NameCerner Result PDM
3048800683.0 BNP BNP BNP BNP 5901640